Green Spring SARS-CoV-2 Antigen Rapid Test Kit - Buy Green Spring Rapid Test
31,50 €*
Green Spring SARS-CoV-2 Antigen Rapid Test Kit
Simplify COVID-19 detection with the Green Spring SARS-CoV-2 Antigen Rapid Test Kit. Delivering reliable results in 15 minutes, this kit is designed for professional use, ensuring swift response times in clinical settings.
In high-pressure scenarios, such as a symptomatic patient requiring immediate attention, the Green Spring SARS-CoV-2 Antigen Rapid Test Kit stands ready as the go-to tool for healthcare professionals. Trust in this kit to provide not just swift and accurate results, but also the confidence needed to act quickly in the fight against COVID-19. The Green Spring Rapid Test Kit is offered at a reasonable price while maintaining high-quality standards.
Product Specifications
- 4 in 1 sampling options: nasal, nasopharyngeal, oropharyngeal, saliva - (lollipop)
- Easy-to-use with integrated buffer solution
- Capable of detecting the Omicron variant
- Results available in just 15 minutes
- 96.77% sensitivity and 100% specificity for accurate diagnosis
- No equipment needed for testing
- CE certification confirms compliance with EU standards
- 25 Tests Per Box
Benefits
- Rapid results contribute to effective public health management
- CE-certified kit ensures quality and regulatory compliance
- Cost-effective solution, supporting healthcare budgets
- User-friendly design reduces training needs for medical professionals
- Confirmed by the Paul Ehrlich Institute: 1st place among rapid tests
- Saliva - (lollipop) test method
- Money-Back Guarantee: Assured customer satisfaction with a 14-day return policy
Comparison - Professional COVID-19 Antigen Rapid Tests | |||||||
---|---|---|---|---|---|---|---|
Manufactured by | Hecin | Testsealabs | Bioteke | Longsee | Green Spring | Roche | Siemens |
Sensitivity | 97.09% | 92.10% | 96.49% | 95.51% | 96.77% | 96.52% | 97.25% |
Specificity | 99.78% | 98.10% | 99.28% | 99.72% | 100% | 99.60% | 100% |
Manufactured in | China | China | China | China | China | South Korea | China |
Listed for the "EU common list" |
Yes, in category A | Yes | Yes, in category A | Yes, in category A | Yes, in category A | Yes, in category A | Yes, in category A |
Technical Data
Box: 25 pcs / Carton: 40 boxes - 1000 pieces
Listed on the Common RAT List of the HSC
CE-certified for use in the European market
BfArM listed, Test-ID: AT417/20
Kit includes 25 test cassettes, 25 sterile swabs, 25 extraction tubes, and a tube stand
Storage: Shipment within 1-3 business days
Standards and market conformity: Professional use, EN ISO 13485:2016, identified for EU-wide recognition
Included within the Green Spring SARS-CoV-2 Antigen Rapid Test Kit 4 in 1 are the following components:
25 sterile swabs
25 test cassettes
25 extraction tubes
1 tube stand
1 user manual
Green Spring Rapid Test Kit - Frequently Asked Questions
What does the Green Spring Rapid Test Kit entail?
The Green Spring Test Kit is a rapid COVID-19 antigen test with high specificity and sensitivity. It has been evaluated by the Paul Ehrlich Institute and differs from other rapid tests by offering 4 options for sample collection (nasal, nasopharyngeal, oropharyngeal, or saliva swab).
Is it possible for the Green Spring Rapid Test Kit to detect mutations?
Yes, the Green Spring 4-in-1 COVID-19 antigen rapid test can detect, among other variants, the Delta and Omicron variants.
Is the Green Spring Rapid Test safe Nasal / Lollipop Testing?
The Green Spring Test has been evaluated by the PEI and has an overall sensitivity of 100%. The test's sensitivity is 95.51% and specificity is 99.72%. Since the test is on the "Common List" (European Commission list), it can be assumed to be safe.
How long does it take to get the results of the Green Spring SARS-CoV-2 Antigen Rapid Test Kit?
You can read the results of the Green Spring test in just 15 minutes.
Is the Green Spring test suitable for children?
Yes, the Green Spring Test is more suitable for children than other tests, especially because it can be done with lollipops.
How is the professional Green Spring 4 in 1 antigen test - Rapid Test packaged?
There are 25 tests in one box, and 1000 in one whole carton.
How long is the Green Spring SARS-CoV-2 Antigen Rapid Test Kit - Green Spring Rapid Test storable?
The Green Spring SARS-CoV-2 Antigen Rapid Test can be stored at room temperature or between 4 and 35 degrees for up to 12 months.
Does the Green Spring Rapid Test detect the Omicron variant?
Yes, the tests have been evaluated by the Paul-Ehrlich-Institut. The Omicron variant is detected in full.
Which tests are on the Paul-Ehrlich-Institut's checklist?
The list includes tests that meet the sensitivity criteria and are in the top 20% of the list. You can read the exact details here.
Who is allowed to use the Green Spring colloidal gold Rapid Test?
These tests are exclusively intended for professional use. Home antigen tests can be found here.
Why Buy the Green Spring SARS-CoV-2 Antigen Rapid Test Kit - Green Spring Rapid Test?
✓ MONEY-BACK GUARANTEE
Our goal is your satisfaction with your purchase. If the purchased goods do not meet your expectations, you can return them within the 14-day cancellation period and you will be refunded the purchase price.
Green Spring SARS-CoV-2 Antigen Rapid Test Kit Test Instructions
Rapid test for the qualitative detection of SARS-CoV-2 nucleocapsid antigens. For professional use.
PURPOSE
The Green Spring® SARS-CoV-2 Antigen Rapid Test is for the rapid qualitative detection of SARS-CoV-2 nucleocapsid protein antigen in human saliva, nasal, nasopharyngeal or throat swab specimens. The results are used for the detection of SARS-CoV-2 antigen. The antigen is generally detectable in upper respiratory tract specimens during the acute phase of infections. Positive results do not rule out bacterial infection or co-infection with other viruses. The pathogen detected may not be the sole cause of the disease. Negative results should be treated as suspected cases and confirmed with a molecular assay. Negative results should be considered in the context of a patient's recent exposures, history and presence of clinical signs and symptoms consistent with COVID-19. These tests should only be used by professionals or trained individuals.
SUMMARY
The novel coronaviruses belong to a ß-genus. COVID-19 is an acute respiratory infectious disease. Humans are generally susceptible to it. Currently, patients infected with the novel coronavirus are the main source of infection; asymptomatically infected people may also be a source of infection. The main manifestations include fever, fatigue and a dry cough. A stuffy or runny nose, sore throat, muscle aches and diarrhoea occur in a few cases.
TEST PRINCIPLE
The Green Spring® SARS-CoV-2 Antigen Rapid Test is a qualitative, membrane-based immunoassay for the detection of SARS-CoV-2 nucleocapsid protein antigens. The test line region is coated with SARS-CoV-2 antibody. The sample reacts with the SARS-CoV-2 antibody in the test line region. If the sample contains SARS-CoV-2 antigens, a coloured line appears in the test line area (T) as a relevant result. As a procedural control, a coloured line appears in the control line area (C), indicating that the correct volume of sample has been added and membrane wetting has occurred correctly
STORAGE AND STABILITY
Store the tests in the sealed foil pouch at room temperature or refrigerated (2 - 30 °C). The test is stable until the expiry date printed on it. The test cassettes must be stored in the sealed foil pouch until use. Do not freeze. Do not use after the expiry date. Protect from sun, moisture and heat.
MATERIALS SUPPLIED
• Test cassette with one pack of desiccant: 25 pieces
• Sterile swab: 25 pieces
• Extraction tubes with buffer: 25 disposable extraction tubes with 0.5 ml extraction buffer each and 25 nozzle caps.
• Workstation: 1 piece
• Package insert: 1 instruction leaflet
Precautionary Measures
1. The package leaflet must be read carefully before performing the test. Failure to follow the instructions in the package leaflet may lead to inaccurate test results.
2. For professional use in in vitro diagnostics only. Do not use after the expiry date.
3. Do not eat, drink or smoke for 10 minutes before and during sample collection.
4. Do not use the test if the packaging or test components are damaged.
5. All specimens must be considered potentially infectious. Observe established precautions against microbiological hazards throughout the collection, handling, storage and disposal of patient specimens and used test components.
6. Wear protective clothing such as lab coats, disposable gloves and eye protection while samples are being examined
7. Wash your hands thoroughly after performing the test.
8. Samples stored in viral transport media (VTM) may influence test results.
9. All used test components should be disposed of according to local regulations.
10. Humidity and temperature can adversely affect the results
PREPARATION
Only use the materials supplied with the respective set. Test the samples immediately
Use the test kit only at room temperature (15 to 30 °C). The test kit is intended only for swab specimens that are collected and tested directly (i.e. swabs that have NOT been placed in transport media). This kit is NOT intended for testing liquid specimens such as wash or aspirate specimens or swabs in transport media, as results may be affected by dilution.
1. Tear off the foil pouch, remove the test cassette and place it on a clean and flat surface.
2. Freshly collected samples should be processed within 1 hour.
3. Label the respective test cassette for each test or control.
4. Place the labelled extraction tubes in a rack in the designated area of the workspace.
SAMPLING
The correct sample collection is the most important step. Choose one of the four methods and then proceed with the test procedure.
1) Salvia (Lolli-Test)
Be aware that false results may occur if saliva is not collected properly.
1. Place an extraction tube in the cardboard workstation.
2. Press the tip of the tongue against the lower root of the jaw. Cough deeply. Make the sound of "kuuua" to concentrate the saliva.
3. Place the swab on the tongue for at least 10 seconds, turning it 3 times or more to fully absorb the saliva.
2) Anterio-nasal swab (nose in front)
Make sure to collect enough nasal secretions with the swab. It is advisable to blow your nose first.
1. Place an extraction tube in the cardboard workstation.
2. Carefully insert the swab into the patient's nostril. The tip of the swab should be inserted up to 2.5 cm deep from the edge of the nostril.
3. Dab along the mucous membrane in the nostril to ensure that both mucus and cells are collected.
4. Remove the swab from the nostril while gently rotating it between your fingers.
3) Nasopharyngeal swab (nose and throat)
1. Place an extraction tube in the cardboard workstation.
2. Tilt the patient's head slightly backwards. Hold the swab like a pen and insert it through the nostril parallel to the palate.
3. While inserting, gently rub and roll the swab. As soon as you feel the throat resistance, stop and let the swab absorb secretion.
4. Slowly and gently remove the swab outwards while gently rotating it between your fingers.
4) Oropharyngeal swab (throat)
1. Place an extraction tube in the cardboard workstation.
2. Have the patient open his/her mouth wide and make "Ah" sounds, exposing the pharyngeal tonsils on both sides.
3. Hold the swab firmly and wipe back and forth on the pharyngeal tonsils on both sides at least three times per side with moderate force. Do not touch the palate, tongue, teeth or gums.
4. Remove the swab while gently rotating it between your fingers.
For best results, the nasopharyngeal (nose to throat) method is recommended.
TESTING
After taking the sample, perform the test as follows:
1. Tear off the seal of the extraction buffer tube.
2. Insert the swab into the tube and dip it up and down into the liquid for at least 10 seconds. Then hold the swab against the bottom of the tube and turn it 3 times, making sure that no contents splash out of the tube.
3. Remove the swab while squeezing the sides of the tube to extract the liquid from the swab.
4. Place the dropper tip firmly on the extraction buffer tube and mix the liquid thoroughly.
5. Add 3 drops (approx. 100μL) via the dropper tip into the sample well of the test cassette.
6. Evaluate the test results after 15 minutes. Do not evaluate the results after 20 minutes.
INTERPRETATION OF THE TEST RESULT
POSITIVE: Two lines appear. One coloured line appears in the control line region (C) and another coloured line appears in the test line region (T). A positive result in the test region indicates the detection of SARS-CoV-2 antigens in the sample. A positive result does not exclude infection with other pathogens
NEGATIVE: A coloured line appears in the control area (C). No visible coloured line appears in the test line area (T). A negative result does not rule out viral infection with SARS-CoV-2 and should be confirmed by molecular diagnostic methods if COVID-19 is suspected.
INVALID: The control line does not appear. Insufficient sample volume or incorrect handling are the most likely reasons for the control line not appearing. Check the procedure and repeat the test with a new test cassette. If the problem persists, stop using the test kit immediately and contact your dealer.
QUALITY CONTROL
The control area (C) serves as an internal procedure control. A coloured line appears when the procedure or sample volume has been applied correctly. Control standards are not supplied with this test. As good laboratory practice, it is recommended that positive and negative controls be performed regularly to verify test performance.
RESTRICTIONS
• This test is intended for the qualitative detection of SARS-CoV-2 viral antigens only. The exact concentration of SARS-CoV-2 virus antigens cannot be determined in this test.
• Test results are for clinical reference only and should not be the sole basis for clinical diagnosis and treatment. Clinical management of patients should be considered in combination with their symptoms, physical signs, patient history, other laboratory tests, therapeutic responses and epidemiological information.
• Proper sample collection is crucial. Failure to follow the procedure can lead to inaccurate test results. Improper collection, storage or even freezing and thawing of the sample can lead to inaccurate test results.
• A false-negative test result may occur if the viral antigen level in a sample is below the detection limit of the test or if the sample was not collected or transported properly; therefore, a negative test result does not rule out the possibility of SARSCoV-2 infection.
• A positive result does not exclude co-infection with other pathogens.
• Monoclonal antibodies may not recognise SARS-CoV-2 viruses with slightly altered amino acid levels in the region of the target epitope, or may recognise them with less sensitivity.
• The amount of antigen in a sample may decrease with increasing disease duration. Samples taken after the 5th day of illness are more likely to be negative compared to an RTPCR test.
• The tests target the nucleocapsid proteins. Performance is not affected by mutations in the spike protein. Mutations in the nucleocapsid protein are not excluded in the future.
You can download these instructions here download